All news

Technical

State of health (SoH): what the figure tells you, and why we test every cell

“SoH 85%”: on a spec sheet, the figure is reassuring. But what does it really measure, and what does it leave out? For a battery starting a second life, state of health is the data point that decides everything. Provided you know how it was obtained.

4 min readRevaw

Visual of the Revaw battery

SoH, a simple definition

SoH (state of health) compares a battery with what it was when it left the factory. The EU Batteries Regulation defines it as “a measure of the general condition of a rechargeable battery and its ability to deliver the specified performance compared with its initial condition” (Article 3).

In practice, it is most often expressed through capacity. A cell designed for 280 Ah that now delivers only 252 Ah has an SoH of 90%.

Why a battery leaves a car at around 70 to 80%

An electric car battery is not “finished” when it comes out of the vehicle. It simply no longer meets the demands of driving: range, power when accelerating, fast charging.

According to work by the European Commission’s Joint Research Centre, cited by the European platform Rebattex, a car battery usually retains around 70 to 80% of its original capacity when it leaves the vehicle. The actual condition varies a great deal from one battery to the next and must be assessed case by case.

Carmakers now have figures to meet. The Euro 7 standard requires electric cars to keep at least 80% of their energy for 5 years or 100,000 km, then 72% up to 8 years or 160,000 km.

Battery durability thresholds set by Euro 7Electric passenger cars, minimum guaranteed energy
  1. First registration100%
  2. 5 years or 100,000 km80%
  3. 8 years or 160,000 km72%

Source: Regulation (EU) 2024/1257 (Euro 7), Annex II

A battery removed at 75% keeps three quarters of its capacity. For a household storing its daytime solar output for the evening, that is plenty. You still need to know what that percentage hides.

What SoH does not tell you

One overall figure hides the differences

An SoH given for a whole battery is an average, or an estimate from the battery management system (BMS). It says nothing about the differences between the cells inside it.

Yet in a string of cells in series, the weakest one sets the limit:

  • when charging, everything stops when the first cell is full;
  • when discharging, everything stops when the first cell is empty.

One tired cell in a string of fifteen therefore holds back the other fourteen. A pack “at 85%” can behave, in real use, like its weakest cell.

Capacity is not the only criterion

For stationary storage batteries, the EU regulation lists the parameters that describe state of health (Annex VII):

  1. remaining capacity;
  2. where possible, remaining power capability;
  3. where possible, remaining round-trip efficiency;
  4. the evolution of self-discharge rates;
  5. where possible, ohmic resistance.

The same text also lists the data used to estimate remaining lifetime: total energy throughput, number of equivalent full cycles, deep discharge events, time spent at extreme temperatures…

Two cells with the same capacity are therefore not necessarily equal. The one whose internal resistance has risen will run hotter and handle power less well.

How it is measured in practice

There are several ways to assess state of health, some faster, some more reliable.

  • Reading the BMS. It is quick and useful for a first sort. But it is an estimate, calculated by software designed for the original car.
  • Measuring capacity. You charge and discharge fully, with controlled current and temperature. It is the benchmark, but it takes time.
  • Measuring internal resistance. You send a current pulse and watch the voltage drop. It is a good indicator of ageing and of how well the cell handles power.
  • Tracking self-discharge. You leave the cell at rest and monitor its voltage. A cell that drains on its own gives away a fault.

For LFP, real measurement is essential. Its voltage barely changes between almost empty and almost full: you cannot judge an LFP cell by its voltage alone.

That is why, at Revaw, every cell is measured one by one, on test benches and with control software developed by our team. Only the cells that hold up go back into service. They are then matched, meaning grouped by similar characteristics. The three blocks of fifteen cells in a 13 kWh battery thus age at the same pace, with no weak link.

What the law already requires

The EU Batteries Regulation has made state of health a data point in its own right.

  • Since 18 August 2024, the management system of stationary storage batteries must hold up-to-date data on their state of health and expected lifetime (Article 14). The buyer has read access, in particular to assess the battery’s residual value.
  • For a battery that ceases to be waste in order to be repurposed, proof is needed that a state-of-health assessment was carried out in an EU Member State. It must also be shown that the battery reaches the performance level of its new use (Article 73). This information must be included in the documentation given to the end user.
  • From 18 February 2027, every battery above 2 kWh will have its digital passport, accessible through a QR code (Article 77). We cover these deadlines in our article on the EU Batteries Regulation.

Three reflexes for installers

  1. Ask how the SoH was obtained. BMS reading, full capacity test, cell by cell or whole pack? The figure is only as good as its method.
  2. Look at the warranty in energy, not just in years. A commitment in kWh delivered, like the 45,000 kWh of the Revaw 13 kWh battery, tells you in concrete terms what the manufacturer expects from its cells.
  3. Check traceability. A battery passport available through a QR code lets you trace the battery’s history, today and in ten years’ time.

Read next

A question, a project?

Let’s talk about your next installation.

Inverter compatibility, sizing, installer terms: our team will answer.

Contact us